TA-PROUltrafast Transient Absorption Spectrometer

Measure how photoexcited states evolve across wavelength and time. TA-PRO combines configurable probe bands, automated acquisition and optional fluorescence, microscopy and longer-time measurements.

Time-Tech Spectra TA-PRO instrument

Is TA-PRO right for your experiment?

For laboratories needing flexible excitation, multiple detection bands and a route to spatially resolved or extended-time experiments.

Measurement
Ultrafast transient absorption
Laser platform
Ti:sapphire or Yb-based
Acquisition
Transmission / reflection
Expansion
TA-FL, TA-Micro, TA-Nano, TCSPC

Applications & suitable samples

Thin films & photovoltaics

Follow transient spectral features and wavelength-dependent recovery after excitation. Compare samples under controlled pump fluence and geometry.

Semiconductors & 2D materials

Resolve dynamics in UV, visible or NIR bands. Spatially resolved investigations require the TA-Micro option.

Photophysics

Collect spectra and kinetic traces for excited-state studies; add fluorescence measurements when emission dynamics are also needed.

Explore perovskite measurement selection

Specifications & configuration

Manufacturer-listed values below distinguish the measurement parameter from its configuration conditions. The final quotation defines the supplied system.

TA-PRO specification guide
ParameterPublished value / capabilityConfiguration condition
Ti:sapphire probe bands330-650, 430-800 or 850-1500 nmSelectable bands; 280-380 nm is optional.
Yb-based probe bands400-600, 500-950 or 1100-1600 nmSelectable bands. Supplier notes increased noise near 515 nm.
Delay window8 ns listed in current manufacturer datasheetConfirm the ordered laser/delay-line combination; not a microsecond window.
Instrument response (IRF)≤1.5 × excitation pulse widthSystem response depends on the excitation and optical configuration.
Sensitivity≤10⁻⁶ ODRequires the optional 100 kHz high-speed camera; acquisition conditions apply.
Visible detector8 kHz defaultNIR and 100 kHz detectors are configuration choices.
High-speed scan90 delay points in 10 sManufacturer high-speed mode; not a guarantee for every sample or scan.
Measurement geometryTransmission / reflectionSelect appropriate sample holder and optical access.
Sample formatsSolutions, films and powdersEnvironmental accessories require compatibility review.
Automation & softwareOptical-path switching, calibration, acquisition, analysis and fittingConfirm required analysis outputs in the configuration.

Probe ranges are separate configuration choices, not one continuous band supplied with every instrument. The supplier also illustrates extended probe coverage to 2200 nm; request a confirmed laser, optics and detector specification for that range.

Source: Time-Tech Spectra TA-PRO and the manufacturer model brochure. Reviewed 7 October 2026.

Expansion modules for TA-PRO

These upgrades belong to TA-PRO and are specified separately from the base ultrafast system.

TA-FL · ultrafast fluorescence

Adds emission dynamics alongside absorption. Fluorescence upconversion and Kerr-gate detection are different configurations, not interchangeable specifications.

TA-FL · ultrafast fluorescence configuration
Upconversion360-950 nm detection; 8 ns window; IRF ≤1.4 × pulse width.
Kerr gate355-1100 nm spectral range; ≤1 ps timing; 8 ns window.
ConfigurationPublished detailed specifications are paired with a 1030 nm laser; confirm the required emission band and mode.
TA-Micro · spatially resolved TA

Adds microscopic spectroscopy and TA imaging for micro- and nanoscale samples.

TA-Micro · spatially resolved TA configuration
ImagingMicro-spectroscopy, wide-field TA and carrier-migration modes.
Resolution<500 nm spatial resolution; <50 nm carrier-migration accuracy, manufacturer specifications.
Detection400-800 nm or optional NIR 900-1700 nm camera range; 10×, 40×, 50× and 100× objectives.
TA-Nano · longer-time dynamics

Extends TA-PRO to longer-lived processes through a separate nanosecond measurement configuration.

TA-Nano · longer-time dynamics configuration
Coverage360-1700 nm; time window ≤400 μs.
Timing1 ns optical-pump or 8 ns electrical-pump detection resolution.
Sensitivity≤0.2 mOD; transmission/reflection modes. Electrical pumping requires the relevant extension.
TCSPC · fluorescence lifetime

Adds time-correlated single-photon counting for a complementary fluorescence-lifetime measurement.

TCSPC · fluorescence lifetime configuration
Timing≤100 ps module time resolution listed by the manufacturer.
SelectionSpecify excitation, detector band, lifetime range and complete system IRF.

Measurement examples

Original Time-Tech Spectra figures, not HX measurements. Axes, scales and plotted data are retained. Example performance depends on the sample and acquisition conditions.

Perovskite film · UV-visible dynamics

A spectral map locates transient features; traces follow their evolution at selected wavelengths. These measurements support comparison of photoexcited-state dynamics without assigning a unique mechanism from the image alone.

Perovskite film · 405 nm excitation · five scans · 150 delay points.

Wavelength-delay map
Wavelength-delay map
Selected kinetic traces
Selected kinetic traces

ZnO · deep-UV measurement

The UV example extends the application range to a wide-bandgap semiconductor. Check both pump generation and UV probe optics before choosing this configuration.

ZnO · 257.5 nm excitation · three scans · 150 delay points.

ZnO transient absorption map
ZnO transient absorption map
ZnO kinetic traces
ZnO kinetic traces

Bulk MoS₂ · visible measurement

Compare the spectral evolution and recovery of a 2D-material sample. The figures are bulk MoS₂ data; they should not be presented as a measurement on a specific heterostructure.

Bulk MoS₂ · 515 nm excitation · three scans · 150 delay points.

MoS₂ transient absorption map
MoS₂ transient absorption map
MoS₂ kinetic traces
MoS₂ kinetic traces

Figure source: Time-Tech Spectra TA-PRO measurement examples.

Plan your configuration

Information to prepare for TA-PRO
Existing laserProvide wavelength, pulse width, repetition rate and available pulse energy. Confirm whether the proposed system includes the laser.
Sample & environmentState sample size, optical density, substrate and whether reflection, a cryostat, magnetic field or a diamond anvil cell is needed.
InstallationRequest the configuration-specific footprint, optical-table requirements, power, cooling and laser-safety provisions before planning laboratory space.

Selection questions

Does TA-PRO cover femtoseconds to microseconds as standard?

No. The ultrafast delay window and the optional TA-Nano measurement window must be specified separately. TA-Nano is an upgrade to TA-PRO, not an assumed feature of TA-LITE or FP100.

Which information helps HX select a configuration?

Send sample format, pump wavelength, probe band, earliest and latest dynamics of interest, and any existing laser specifications. Include sample-environment constraints.

Compare TA-PRO, TA-LITE and FP100

Brochure & Singapore enquiries

Send HX your sample, target measurement and configuration requirements. We will help identify the questions to resolve with Time-Tech Spectra.

TA-PRO manufacturer brochure. Original supplier PDF.

You can also contact sales@hxtech.sg.