TA-LITECompact Femtosecond Transient Absorption System

A defined femtosecond laser and visible probe configuration for measuring photoinduced spectral changes in solutions, films and powders.

Time-Tech Spectra TA-LITE instrument

Is TA-LITE right for your experiment?

For experiments suited to 515 or 343 nm excitation and visible probing, with an optional extension toward the UV.

Probe band
480-950 nm
Excitation
515 / 343 nm
Laser pulse width
350 fs
Delay window
4 ns

Applications & suitable samples

Materials screening

Compare transient spectral responses across a series of films or solutions using consistent excitation conditions.

Visible excited-state dynamics

Follow wavelength-dependent signals and kinetic traces within the visible probe band.

UV excitation studies

Use the 343 nm harmonic where appropriate; distinguish this pump wavelength from the optional 380 nm probe extension.

Explore perovskite measurement selection

Specifications & configuration

Manufacturer-listed values below distinguish the measurement parameter from its configuration conditions. The final quotation defines the supplied system.

TA-LITE specification guide
ParameterPublished value / capabilityConfiguration condition
Laser platform1030 nm femtosecond laserManufacturer-described integrated excitation platform.
Pulse width350 fsLaser specification, not the complete instrument response.
Repetition rate100 kHzMatch sample exposure and signal requirements.
Excitation515 nm (SHG); 343 nm (THG)Harmonic-generation configuration.
Probe band480-950 nmExtendable to 380 nm; specify the extension separately.
Delay window4 nsCurrent specification; example plots may reflect a different measurement configuration.
Sensitivity≤0.1 mODManufacturer specification; confirm acquisition conditions.
Instrument response (IRF)≤1.5 × pulse widthVerify the actual system response for the chosen wavelengths.
Geometry & samplesTransmission/reflection; solutions, films and powdersChoose the holder and optical access for the sample.
SoftwareAcquisition, analysis and fittingConfirm export formats and required fitting workflows.

Pump excitation and probe coverage are different specifications. TA-LITE is not presented here as supporting the TA-PRO upgrade modules.

Source: Time-Tech Spectra TA-LITE and the manufacturer model brochure. Reviewed 7 October 2026.

Options & measurement paths

Select the options needed for your measurement; listed choices are not automatically included.

UV probe extension

Extend the nominal 480-950 nm probe coverage toward 380 nm when the required spectral feature lies outside the visible configuration.

UV probe extension configuration
ConfirmRequired shortest probe wavelength, transmission of the sample/substrate, and excitation-scatter rejection.
Sample geometry

Select transmission or reflection around the sample and its substrate.

Sample geometry configuration
ConfirmHolder format, sample dimensions, optical density and exposure limits.

Measurement examples

Original Time-Tech Spectra figures, not HX measurements. Axes, scales and plotted data are retained. Example performance depends on the sample and acquisition conditions.

Bulk MoS₂ · spectra and kinetics

The manufacturer's example combines a wavelength-delay map, spectral slices and selected kinetic traces. Use it to understand the available outputs, not as a promise of identical signal strength on another sample.

Bulk MoS₂ · 515 nm excitation · visible probing. The plotted delay extends beyond the current 4 ns specification; confirm the applicable configuration with HX.

MoS₂ wavelength-delay map, spectral slices and kinetic traces
MoS₂ wavelength-delay map, spectral slices and kinetic traces

Figure source: Time-Tech Spectra TA-LITE measurement examples.

Plan your configuration

Information to prepare for TA-LITE
Sample exposureProvide absorption, substrate and damage/photostability limits so excitation energy and repetition rate can be assessed.
Laboratory layoutThe model brochure includes an instrument layout. Confirm complete installed dimensions, laser-safety controls and utilities for the quoted configuration.
Measurement targetIdentify the probe wavelengths and fastest/slowest dynamics required before choosing TA-LITE over TA-PRO or FP100.

Selection questions

Is the 380 nm option a new excitation wavelength?

No. It extends the probe range. The listed harmonic excitation wavelengths are 515 nm and 343 nm.

When should I consider TA-PRO instead?

When the experiment needs a different laser platform, additional detection bands, microscopy or longer-time expansion. Check compatibility and the intended measurement before selecting.

Compare TA-PRO, TA-LITE and FP100

Brochure & Singapore enquiries

Send HX your sample, target measurement and configuration requirements. We will help identify the questions to resolve with Time-Tech Spectra.

TA-LITE manufacturer brochure. Original supplier PDF.