FLIM500Confocal Fluorescence Lifetime Imaging System

Connect spatial detail with fluorescence intensity, spectra and lifetime. FLIM500 combines a scanning microscope with configurable optical and electrical measurements for materials research.

Time-Tech Spectra FLIM500 instrument

Is FLIM500 right for your experiment?

For local imaging of emitting regions, lifetime variation and carrier dynamics in films, nanostructures and devices.

Measurements
Intensity, spectra & lifetime
Image sampling
Up to 4096 × 4096 pixels
Microscope
Confirm sample geometry
Spatial resolution
≤260 nm with 100× oil

Applications & suitable samples

Emitting materials

Compare bright-field, PL intensity and lifetime maps to locate spatial variations for further study.

Carrier transport

Use fixed excitation and scanning detection to investigate spatial and temporal emission changes.

Optoelectronic devices

Configure electroluminescence or photocurrent imaging around the device contacts, bias and optical-access requirements.

Explore perovskite measurement selection

Specifications & configuration

Manufacturer-listed values below distinguish the measurement parameter from its configuration conditions. The final quotation defines the supplied system.

FLIM500 specification guide
ParameterPublished value / capabilityConfiguration condition
Scanner band400-900 nmGalvanometer scanning system; not the full detector wavelength coverage.
Maximum image sampling4096 × 4096 pixelsPixel count does not specify optical resolution or field of view.
Objectives10×, 50×, 100× air; optional 100× oilConfirm working distance, numerical aperture and sample compatibility.
Spatial resolution≤260 nmManufacturer specification with the 100× oil objective.
Spectrometer300 mm monochromatorSelect PMT or CCD detection.
Spectroscopy detector bandsPMT: 185-900 nm; CCD: 200-1100 nmDetector ranges; usable system range also depends on the optics.
TCSPC detector bandsPMT: 200-870 nm; APD: 400-1100 nmSelect according to emission band and signal level.
TCSPC timing≤70 ps time resolution listed on current supplier webpageModule timing is not a guaranteed complete-system IRF.
TCSPC window5 μs; 4096 binsLong-lifetime expansion available.
Excitation choicesDiscrete picosecond sources from 375 to 1060 nmSelect compatible wavelengths; optional supercontinuum source is not included by default.

Confirm microscope geometry for the quoted configuration: the 2026 catalogue describes an upright platform, while the supplier webpage describes an inverted platform. The sources also use different TCSPC timing descriptions. Confirm the full excitation-detector IRF rather than equating timing electronics with measured lifetime resolution.

Source: Time-Tech Spectra FLIM500 and the supplied 2026 catalogue. Reviewed 7 October 2026.

Options & measurement paths

Select the options needed for your measurement; listed choices are not automatically included.

Excitation & spectroscopy

Choose pulsed excitation, filters and a PMT, APD or CCD path around the sample's absorption and emission.

Excitation & spectroscopy configuration
Source choices375, 405, 440, 480, 510, 635, 665, 690, 850, 940 or 1060 nm picosecond sources.
Supercontinuum410-2400 nm source listed as an option; this does not extend every microscope or detector path to that range.
Sample environment

The manufacturer demonstrates low-temperature and high-pressure imaging configurations.

Sample environment configuration
CompatibilityCheck chamber geometry, objective working distance, thermal conditions and optical access.
Electrical & carrier imaging

Add device-contact and acquisition arrangements for electrical or carrier-dynamics studies.

Electrical & carrier imaging configuration
Device inputsProvide contact drawings, bias/pulse conditions and whether EL, photocurrent or fixed-excitation carrier imaging is required.

Measurement examples

Original Time-Tech Spectra figures, not HX measurements. Axes, scales and plotted data are retained. Example performance depends on the sample and acquisition conditions.

MAPbI₃ nanowires · intensity and lifetime

Compare a bright-field view with emission intensity and lifetime information. A bright region alone does not establish a longer lifetime or improved material quality.

MAPbI₃ nanowires · 400 nm excitation · 100× objective.

Nanowire bright-field, PL intensity and lifetime images
Nanowire bright-field, PL intensity and lifetime images

Carrier migration · fixed excitation

A fixed excitation position and time-resolved images reveal how the detected fluorescence distribution evolves along the nanowire.

MAPbI₃ nanowires · 400 nm excitation · 100× objective. Manufacturer carrier-migration example.

Fixed-excitation nanowire fluorescence and time-division images
Fixed-excitation nanowire fluorescence and time-division images

Perovskite device · photocurrent mapping

Spatial photocurrent information complements optical emission measurements. Electrical contacting and the relevant measurement interface must be included in the configuration.

Perovskite solar-cell device · 405 nm excitation · 100× objective.

Perovskite device photocurrent mapping
Perovskite device photocurrent mapping

Figure source: Time-Tech Spectra FLIM500 measurement examples.

Plan your configuration

Information to prepare for FLIM500
Sample geometrySend substrate thickness, sample size and which side is accessible to the objective. Confirm upright or inverted geometry with HX Technology.
Signal & imagingProvide emission band, expected lifetime, field of view and required spatial detail; state any photobleaching limits.
Environment & installationConfirm chamber or contact access, vibration isolation, instrument footprint, power and laser-safety needs for the complete configuration.

Selection questions

Does a 4096 × 4096 image guarantee 260 nm resolution?

No. Image sampling, field of view and optical resolution are different. The stated spatial resolution requires the specified oil objective and suitable measurement conditions.

When should I compare Solarium-L?

When the main question concerns photovoltaic material or device performance, including PLQE, QFLS or pseudo-J-V mapping. FLIM500 emphasises local fluorescence and lifetime imaging.

Compare FLIM500 and Solarium-L

Brochure & Singapore enquiries

Send HX your sample, target measurement and configuration requirements. We will help identify the questions to resolve with Time-Tech Spectra.

FLIM500 - 2026 catalogue excerpt. Original catalogue pages 22-27 (printed pages 15-20). Source pages are reproduced unchanged.