Confocal 3D surface profiling

Move from a surface image to a height measurement. Plan optical access, lateral sampling and the vertical scan around your microstructure.

Define the surface before choosing the setup

A confocal measurement rejects out-of-focus signal. With suitable scanning and calibration, the axial response can be used to reconstruct surface height. Reflectivity, steep slopes and transparent layers can complicate the result, so representative samples matter.

RequirementWhy it mattersInformation to provide
Feature size and field of viewSets the required sampling and scan areaSmallest feature and total area
Height range and slopesInfluences focus travel and collected signalRelief depth and steepest expected slopes
Material and optical accessDetermines the available return signalSubstrate, coating, transparency and clearance
Existing microscope or OEM platformSets the mechanical and optical interfacesObjective, mounting drawings, detector and control interfaces

Measured with CoraScan

Existing HX demonstration results on fabricated grayscale microstructures. The dimensions below describe these examples, not a general accuracy specification.

CoraScan measured Fresnel lens 3D profile
Fresnel lens1.0 × 1.0 mm area; 6.6 micrometres relief; 1.0 micrometre pitch.
CoraScan measured spiral gradient 3D surface
Spiral height gradient1.0 × 1.0 mm area; 11.8 micrometres height range.

Source: HX CoraScan product demonstrations. Discuss calibration, repeatability and sample suitability separately.

Build a configuration around the sample

CoraScan provides a fibre-coupled confocal scan head with dual-galvanometer scanning, detector output and control software. Integration still requires the right optical, mechanical and acquisition interfaces.

  1. Review a representative surface and establish the required output.
  2. Confirm objective, working distance, illumination, pinhole and detector choices.
  3. Plan Z scanning and synchronization with the existing platform.
  4. Define calibration and an acceptance test using relevant samples.

Common integration questions

Can this replace any surface profiler?

No single method fits every surface. Tell us about transparency, roughness, slopes, coating and the uncertainty your measurement can tolerate. Sample evaluation should precede a commitment.

Is the displayed sampling pitch the measurement accuracy?

No. Sampling spacing, optical resolution, repeatability and measurement accuracy are different quantities. The acceptance criteria should specify which one matters to the experiment.

What should an OEM enquiry include?

Available space, interfaces, sample travel, target scan area, environmental constraints, software requirements and a representative sample or drawing.

HX Technology · Singapore

Discuss your surface profiling experiment

Send your sample material, feature dimensions, height range and existing microscope or machine layout. We will review the integration requirements with you.